Repository logo
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Scholalry Output
  3. Publications
  4. Effect of temperature on the acoustic response and stability of size-isolated protein-shelled ultrasound contrast agents and SonoVue
 
  • Details

Effect of temperature on the acoustic response and stability of size-isolated protein-shelled ultrasound contrast agents and SonoVue

Source
Journal of the Acoustical Society of America
ISSN
00014966
Date Issued
2023-04-01
Author(s)
Kaushik, Anuj
Khan, Aaqib H.
Pratibha,
Dalvi, Sameer V.  
Shekhar, Himanshu  
DOI
10.1121/10.0017682
Volume
153
Issue
4
Abstract
Limited work has been reported on the acoustic and physical characterization of protein-shelled UCAs. This study characterized bovine serum albumin (BSA)-shelled microbubbles filled with perfluorobutane gas, along with SonoVue, a clinically approved contrast agent. Broadband attenuation spectroscopy was performed at room (23 ± 0.5 °C) and physiological (37 ± 0.5 °C) temperatures over the period of 20 min for these agents. Three size distributions of BSA-shelled microbubbles, with mean sizes of 1.86 μm (BSA1), 3.54 μm (BSA2), and 4.24 μm (BSA3) used. Viscous and elastic coefficients for the microbubble shell were assessed by fitting de Jong model to the measured attenuation spectra. Stable cavitation thresholds (SCT) and inertial cavitation thresholds (ICT) were assessed at room and physiological temperatures. At 37 °C, a shift in resonance frequency was observed, and the attenuation coefficient was increased relative to the measurement at room temperature. At physiological temperature, SCT and ICT were lower than the room temperature measurement. The ICT was observed to be higher than SCT at both temperatures. These results enhance our understanding of temperature-dependent properties of protein-shelled UCAs. These findings study may guide the rational design of protein-shelled microbubbles and help choose suitable acoustic parameters for applications in imaging and therapy.
Unpaywall
URI
http://repository.iitgn.ac.in/handle/IITG2025/26839
IITGN Knowledge Repository Developed and Managed by Library

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify