Flowpath modification to reduce electrodialysis module size and energy consumption

Show simple item record

dc.contributor.author Patel, Chirag G.
dc.contributor.author Swaminathan, Jaichander
dc.coverage.spatial United States of America
dc.date.accessioned 2025-02-07T08:39:54Z
dc.date.available 2025-02-07T08:39:54Z
dc.date.issued 2025-07
dc.identifier.citation Patel, Chirag G. and Swaminathan, Jaichander, "Flowpath modification to reduce electrodialysis module size and energy consumption", Separation and Purification Technology, DOI: 10.1016/j.seppur.2025.131555, vol. 362, Jul. 2025.
dc.identifier.issn 1383-5866
dc.identifier.issn 1873-3794
dc.identifier.uri https://doi.org/10.1016/j.seppur.2025.131555
dc.identifier.uri https://repository.iitgn.ac.in/handle/123456789/11001
dc.description.abstract Thermodynamic equipartition of ideal electrodialysis (ED) through the time-varying batch operation that maintains a constant current or instantaneous entropy generation rate has been proposed in the literature to reduce its specific energy consumption at fixed module size. In this study, the optimal current density distribution to minimize the specific energy consumption of ED in the presence of diffusive salt and water fluxes is evaluated. The local current density must increase as the salinity difference between the diluate and concentrate streams widens to reduce the impact of diffusive losses, but maintaining such a current density variation requires adjusting the applied potential continuously. As a practical alternative, we propose and numerically evaluate a novel recirculation flow architecture to improve the energetic performance of steady-state ED while using a conventional constant voltage power source. Like other methods that implement equipartition, maximum savings are obtained at a large baseline system size. Unlike multi-staging, no further savings are observed by adding additional recirculation cell pairs beyond two passes. A modified channel aspect ratio to maintain feed flow velocity in the channels is proposed to keep overall pressure drop and pumping energy similar to the baseline design. Energy (at fixed size) and area (at fixed energy consumption) can be reduced compared to conventional single-stage ED by up to 5% and 25% respectively for seawater brine concentration, and 35% and 55% respectively for seawater desalination.
dc.description.statementofresponsibility by Chirag G. Patel and Jaichander Swaminathan
dc.format.extent vol. 362
dc.language.iso en_US
dc.publisher Elsevier
dc.subject Electrodialysis
dc.subject Flowpath modification
dc.subject Serpentine flow
dc.subject Constant voltage
dc.subject Energy improvement
dc.subject Area reduction
dc.title Flowpath modification to reduce electrodialysis module size and energy consumption
dc.type Article
dc.relation.journal Separation and Purification Technology


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Digital Repository


Browse

My Account