Enhancing passive cavitation imaging using pth root compression delay, sum, and integrate beamforming: in vitro and in vivo studies

Show simple item record

dc.contributor.author Singh, Abhinav Kumar
dc.contributor.author Warbal, Pankaj
dc.contributor.author Basterrechea, Katia Flores
dc.contributor.author Bader, Kenneth B.
dc.contributor.author Shekhar, Himanshu
dc.coverage.spatial United States of America
dc.date.accessioned 2025-03-06T09:37:55Z
dc.date.available 2025-03-06T09:37:55Z
dc.date.issued 2025-07
dc.identifier.citation Singh, Abhinav Kumar; Warbal, Pankaj; Basterrechea, Katia Flores; Bader, Kenneth B. and Shekhar, Himanshu, “Enhancing passive cavitation imaging using pth root compression delay, sum, and integrate beamforming: in vitro and in vivo studies”, IEEE Transactions on Biomedical Engineering, DOI: 10.1109/TBME.2025.3540101, vol. 72, no. 7, pp. 2283-2292, Jul. 2025
dc.identifier.issn 0018-9294
dc.identifier.issn 1558-2531
dc.identifier.uri https://doi.org/10.1109/TBME.2025.3540101
dc.identifier.uri https://repository.iitgn.ac.in/handle/123456789/11086
dc.description.abstract Objective: Passive cavitation imaging (PCI) derived metrics can serve as surrogates for the outcome of bubble-mediated therapies. Passive cavitation imaging is limited by poor axial resolution and side lobe artifacts, particularly when algorithms such as delay, sum and integrate (DSI) beamforming are used. Methods to improve PCI performance remain an active research area given the need to balance imaging performance with computational complexity. The current study evaluated pth root compression delay, sum and integrate (prDSI) beamforming for PCI using in vitro and in vivo cavitation data collected with insonation parameters relevant to drug delivery, histotripsy ablation, and combined histotripsy and drug therapy. Methods: First, PCI was performed on a flow phantom perfused with ultrasound contrast agent (SonoVue) exposed to focused ultrasound. Next, the performance of prDSI was assessed on histotripsy bubble clouds generated in a red blood cell (RBC)-doped phantom. Finally, PCI was performed on data collected during histotripsy ablation of a thrombus in the femoral vein of a pig. Acoustic emissions generated by cavitation were recorded and processed with DSI, robust Capon, and prDSI beamforming. The imaging performance was evaluated using the axial width, signal-to-interference ratio, and binary statistical analysis-derived metrics. Results: The prDSI approach demonstrated comparable imaging performance to RCB, both in vitro and in vivo based on binary statistical metrics. Considerable improvement was observed in axial width and signal-to- interference ratio, while incurring only a moderately higher computational cost relative to standard DSI beamforming. Conclusions: The findings of this study demonstrate the potential of prDSI for monitoring of cavitation-mediated therapies.
dc.description.statementofresponsibility by Abhinav Kumar Singh, Pankaj Warbal, Katia Flores Basterrechea, Kenneth B. Bader and Himanshu Shekhar
dc.format.extent vol. 72, no. 7, pp. 2283-2292
dc.language.iso en_US
dc.publisher Institute of Electrical and Electronics Engineers (IEEE)
dc.subject Passive cavitation Imaging
dc.subject Histotripsy
dc.subject Robust capon beamforming
dc.subject Pth root compression delay
dc.subject Sum and integrate
dc.title Enhancing passive cavitation imaging using pth root compression delay, sum, and integrate beamforming: in vitro and in vivo studies
dc.type Article
dc.relation.journal IEEE Transactions on Biomedical Engineering


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Digital Repository


Browse

My Account