Models for strength and stiffness of steel plate shear walls with openings

Show simple item record

dc.contributor.author Khan, Nasar A.
dc.contributor.author Srivastava, Gaurav
dc.date.accessioned 2020-08-21T10:51:22Z
dc.date.available 2020-08-21T10:51:22Z
dc.date.issued 2020-10
dc.identifier.citation Khan, Nasar A. and Srivastava, Gaurav, "Models for strength and stiffness of steel plate shear walls with openings", Structures, DOI: 10.1016/j.istruc.2020.07.037, vol. 27, pp. 2096-2113, Oct. 2020. en_US
dc.identifier.issn 2352-0124
dc.identifier.uri http://dx.doi.org/10.1016/j.istruc.2020.07.037
dc.identifier.uri https://repository.iitgn.ac.in/handle/123456789/5649
dc.description.abstract Steel plate shear walls (SPSWs) are being increasingly used as a lateral load resisting mechanism in buildings, particularly in highly seismic zones. Their lighter weight compared to reinforced concrete (RC) shear walls, more predictable performance, and ability to accommodate openings make them advantageous. While the characterization and design of SPSWs without openings are well understood, a detailed system-level understanding of SPSWs with openings is still lacking. This study assesses the inelastic behavior of SPSW systems with different types of openings to enhance this understanding and provide guidance in design. Models for shear strength and stiffness degradation of SPSW with arbitrarily-located opening are proposed. The study found that the size and location of the openings can have significant effects on the performance of the SPSW system. It was found that it is preferable to have openings of sizes less than 15%, aspect ratio of one, circular shape, and located at the central-bottom location of the plate. This study will enable a more rational design of SPSWs with openings and can serve as a guide for estimation of critical parameters such as the reduced shear strength and initial stiffness of SPSWs in different design scenarios.
dc.description.statementofresponsibility by Nasar Ahmad Khan and Gaurav Srivastava
dc.format.extent vol. 27, pp. 2096-2113
dc.language.iso en_US en_US
dc.publisher Elsevier en_US
dc.subject Steel plate shear walls (SPSWs) en_US
dc.subject Openings en_US
dc.subject Diagonal Tension Field en_US
dc.subject Plastification en_US
dc.subject Strength en_US
dc.subject Stiffness en_US
dc.title Models for strength and stiffness of steel plate shear walls with openings en_US
dc.type Article en_US
dc.relation.journal Structures


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Digital Repository


Browse

My Account