Computational fluid dynamics simulation of earth air heat exchanger combined with the Quonset type greenhouse to develop a sustainable controlled environment

Show simple item record

dc.contributor.author Jilani, Nadim
dc.contributor.author Mohapatra, Pranab K.
dc.coverage.spatial United States of America
dc.date.accessioned 2023-11-09T11:12:59Z
dc.date.available 2023-11-09T11:12:59Z
dc.date.issued 2024-01
dc.identifier.citation Jilani, Nadim and Mohapatra, Pranab K., "Computational fluid dynamics simulation of earth air heat exchanger combined with the Quonset type greenhouse to develop a sustainable controlled environment", Geothermics, DOI: 10.1016/j.geothermics.2023.102845, vol. 116, Jan. 2024.
dc.identifier.issn 0375-6505
dc.identifier.issn 1879-3576
dc.identifier.uri https://doi.org/10.1016/j.geothermics.2023.102845
dc.identifier.uri https://repository.iitgn.ac.in/handle/123456789/9425
dc.description.abstract The current study aims to evaluate the performance of an earth air heat exchanger (EAHE) combined with a Quonset-type greenhouse in a summer climate to create a controlled environment for optimum crop development and energy efficiency. The integrated systems thermal performance and airflow patterns are analyzed using computational fluid dynamics (CFD) models. The result shows that greenhouse room air can be satisfactorily achieved in the comfortable temperature range (27-37 degree celsius) for plant growth by combined EAHE even during the hottest summer days. EAHE reduces greenhouse temperature with a minimum temperature gradient of 17 degree celsius between the ambient and air at the exit of EAHEs after the heat exchanging process. It is observed from the analysis that as the flow rate of air entering into EAHE increases, the greenhouse room's temperature decreases up to 0.5 kg/s; after that, there is no significant change in temperature, which makes 0.5 kg/s the recommended flow rate for the model used in the simulation. Pressure loss is reduced in a multi-pipe EAHE system compared to a single-pipe system. This advantage can increase energy efficiency and lower operating costs in greenhouse cooling. The Quonset GiTPV system generates 29.22 kWh of electrical energy daily, making it self-sustaining.
dc.description.statementofresponsibility by Nadim Jilani and Pranab K. Mohapatra
dc.format.extent vol. 116
dc.language.iso en_US
dc.publisher Elsevier
dc.title Computational fluid dynamics simulation of earth air heat exchanger combined with the Quonset type greenhouse to develop a sustainable controlled environment
dc.type Article
dc.relation.journal Geothermics


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Digital Repository


Browse

My Account