Repository logo
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Scholalry Output
  3. Publications
  4. Field deployment of a 4320-nm quantum cascade laser-based TDLS system to compare the background CO2 levels in Mt. Abu with foreground measurements in Gandhinagar, India
 
  • Details

Field deployment of a 4320-nm quantum cascade laser-based TDLS system to compare the background CO2 levels in Mt. Abu with foreground measurements in Gandhinagar, India

Source
Optical Engineering
ISSN
00913286
Date Issued
2020-02-01
Author(s)
Roy, Anirban
Chawhan, Rohan S.
Chakraborty, Arup Lal  
DOI
10.1117/1.OE.59.2.024110
Volume
59
Issue
2
Abstract
We report on the design, development, and field deployment of a 10-mW, 4320-nm distributed-feedback quantum cascade laser-based tunable diode laser spectroscopy (TDLS) system in India for in situ measurement of atmospheric CO<inf>2</inf>. The portable system was deployed at Mount Abu (24.5926° N, 72.7156° E), a hill station in western India, to carry out week-long measurements of background atmospheric CO<inf>2</inf> using direct detection. The mean mole fraction was estimated to be 396 ± 8 ppm. The system was then deployed in Gandhinagar (23.2156° N, 72.6369° E), the capital of the state of Gujarat, to make foreground measurements over the next week. The mean mole fraction at this location was 503 ± 27 ppm. The difference between the background levels in Mount Abu and foreground levels in Gandhinagar is evident. The detection limit of the system, as measured from an Allan variance analysis, was determined to be 260 ppb for an integration time of 58 s and a path length of 20 cm, which is sufficient for such measurements. Another compact and light-weight TDLS system was also deployed for water vapor measurement. It consisted of a 1392.54-nm distributed feedback laser driven by custom electronics and a digital signal processor to carry out waveform generation, data acquisition, and postprocessing tasks.
Publication link
https://www.spiedigitallibrary.org/journals/optical-engineering/volume-59/issue-2/024110/----Custom-HTML----Field/10.1117/1.OE.59.2.024110.pdf
URI
https://d8.irins.org/handle/IITG2025/24231
Subjects
background carbon dioxide | direct detection | greenhouse gas monitoring | quantum cascade laser | tunable diode laser spectroscopy
IITGN Knowledge Repository Developed and Managed by Library

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify